NVD · CVE-2026-64604 · In the Linux kernel, the following vulnerability has been resolved: KVM: VMX: Grab vmcs12 on CR8 interception update iff vCPU is in guest mode When updating CR8NVD · CVE-2026-64603 · In the Linux kernel, the following vulnerability has been resolved: platform/x86: intel-hid: Protect ACPI notify handler against recursion Since commit e2ffcda1NVD · CVE-2026-64602 · In the Linux kernel, the following vulnerability has been resolved: iio: adc: spear: Initialize completion before requesting IRQ In the report from Jaeyoung ChuNVD · CVE-2026-64601 · In the Linux kernel, the following vulnerability has been resolved: ALSA: us144mkii: capture_urb_complete: redundant usb_anchor_urb corrupts anchor list on eachCISA KEV · CVE-2026-21962 · 10.0 · Oracle HTTP Server and Oracle Weblogic Server Proxy Plug-in Improper Access Control Vulnerability · Added 2026-08-24 · Due 2026-08-27CISA KEV · CVE-2026-73570 · Zimbra Collaboration Suite (ZCS) OS Command Injection Vulnerability · Added 2026-08-21 · Due 2026-08-24NVD · CVE-2026-64604 · In the Linux kernel, the following vulnerability has been resolved: KVM: VMX: Grab vmcs12 on CR8 interception update iff vCPU is in guest mode When updating CR8NVD · CVE-2026-64603 · In the Linux kernel, the following vulnerability has been resolved: platform/x86: intel-hid: Protect ACPI notify handler against recursion Since commit e2ffcda1NVD · CVE-2026-64602 · In the Linux kernel, the following vulnerability has been resolved: iio: adc: spear: Initialize completion before requesting IRQ In the report from Jaeyoung ChuNVD · CVE-2026-64601 · In the Linux kernel, the following vulnerability has been resolved: ALSA: us144mkii: capture_urb_complete: redundant usb_anchor_urb corrupts anchor list on eachCISA KEV · CVE-2026-21962 · 10.0 · Oracle HTTP Server and Oracle Weblogic Server Proxy Plug-in Improper Access Control Vulnerability · Added 2026-08-24 · Due 2026-08-27CISA KEV · CVE-2026-73570 · Zimbra Collaboration Suite (ZCS) OS Command Injection Vulnerability · Added 2026-08-21 · Due 2026-08-24

Vendors · growatt

growatt

· 5 Critical

Total CVEs

35

Critical

5

Products

3

Search All CVEs →

35

Recent Vulnerabilities

View all 35
CVE-2025-36753CRITICAL 9.8

The SWD debug interface on the Growatt ShineLan-X communication dongle is available by default, allowing an attacker to attain debug access to the device and to extracting secrets or domains from within the device

CVE-2025-36752CRITICAL 9.8

Growatt ShineLan-X communication dongle has an undocumented backup account with undocumented credentials which allows significant level access to the device, such as allowing any attacker to access the Setting Center. This means that this is effectively backdoor for all devices utilizing a Growatt ShineLan-X communication dongle.

CVE-2025-36750MEDIUM 5.4

ShineLan-X contains a stored cross site scripting (XSS) vulnerability in the Plant Name field. A HTML payload will be displayed on the plant management page via a direct post. This may allow attackers to force a legitimate user’s browser’s JavaScript engine to run malicious code.

CVE-2025-36748MEDIUM 5.4

ShineLan-X contains a stored cross site scripting (XSS) vulnerability in the local configuration web server. The JavaScript code snippet can be inserted in the communication module’s settings center. This may allow attackers to force a legitimate user’s browser’s JavaScript engine to run malicious code.

CVE-2025-36747CRITICAL 9.8

ShineLan-X contains a set of credentials for an FTP server was found within the firmware, allowing testers to establish an insecure FTP connection with the server. This may allow an attacker to replace legitimate files being deployed to devices with their own malicious versions, since the firmware signature verification is not enforced.

CVE-2025-31950MEDIUM 5.3

An unauthenticated attacker can obtain EV charger energy consumption information of other users.

CVE-2025-31945MEDIUM 5.3

An unauthenticated attacker can obtain other users' charger information.

CVE-2025-31654MEDIUM 5.3

An attacker can get information about the groups of the smart home devices for arbitrary users (i.e., "rooms").

CVE-2025-31360MEDIUM 6.5

Unauthenticated attackers can trigger device actions associated with specific "scenes" of arbitrary users.

CVE-2025-31147MEDIUM 5.3

Unauthenticated attackers can query information about total energy consumed by EV chargers of arbitrary users.

CVE-2025-30512MEDIUM 6.5

Unauthenticated attackers can send configuration settings to device and possible perform physical actions remotely (e.g., on/off).

CVE-2025-30510CRITICAL 9.8

An attacker can upload an arbitrary file instead of a plant image.

CVE-2025-30257MEDIUM 5.3

Unauthenticated attackers can retrieve serial number of smart meters associated to a specific user account.

CVE-2025-27929MEDIUM 5.3

Unauthenticated attackers can retrieve full list of users associated with arbitrary accounts.

CVE-2025-27927MEDIUM 5.3

An unauthenticated attackers can obtain a list of smart devices by knowing a valid username through an unprotected API.

CVE-2025-27719MEDIUM 5.3

Unauthenticated attackers can query an API endpoint and get device details.

CVE-2025-27575MEDIUM 5.3

An unauthenticated attacker can obtain EV charger version and firmware upgrading history by knowing the charger ID.

CVE-2025-27565MEDIUM 5.3

An unauthenticated attacker can delete any user's "rooms" by knowing the user's and room IDs.

CVE-2025-27561MEDIUM 5.3

Unauthenticated attackers can rename "rooms" of arbitrary users.

CVE-2025-26857MEDIUM 5.3

Unauthenticated attackers can rename arbitrary devices of arbitrary users (i.e., EV chargers).

CVE-2025-25276MEDIUM 5.3

An unauthenticated attacker can hijack other users' devices and potentially control them.

CVE-2025-24850MEDIUM 5.3

An attacker can export other users' plant information.

CVE-2025-24315MEDIUM 5.3

Unauthenticated attackers can add devices of other users to their scenes (or arbitrary scenes of other arbitrary users).

CVE-2025-24297CRITICAL 9.8

Due to lack of server-side input validation, attackers can inject malicious JavaScript code into users personal spaces of the web portal.

CVE-2025-31949MEDIUM 5.3

An authenticated attacker can obtain any plant name by knowing the plant ID.