NVD · CVE-2026-64604 · In the Linux kernel, the following vulnerability has been resolved: KVM: VMX: Grab vmcs12 on CR8 interception update iff vCPU is in guest mode When updating CR8NVD · CVE-2026-64603 · In the Linux kernel, the following vulnerability has been resolved: platform/x86: intel-hid: Protect ACPI notify handler against recursion Since commit e2ffcda1NVD · CVE-2026-64602 · In the Linux kernel, the following vulnerability has been resolved: iio: adc: spear: Initialize completion before requesting IRQ In the report from Jaeyoung ChuNVD · CVE-2026-64601 · In the Linux kernel, the following vulnerability has been resolved: ALSA: us144mkii: capture_urb_complete: redundant usb_anchor_urb corrupts anchor list on eachCISA KEV · CVE-2026-20349 · Cisco Secure Firewall Adaptive Security Appliance (ASA) and Secure Firewall Threat Defense (FTD) Heap Inspection Vulnerability · Added 2026-08-11 · Due 2026-08-14CISA KEV · CVE-2026-68820 · Microsoft Windows Ancillary Function Driver for WinSock Use-After-Free Vulnerability · Added 2026-08-11 · Due 2026-08-25NVD · CVE-2026-64604 · In the Linux kernel, the following vulnerability has been resolved: KVM: VMX: Grab vmcs12 on CR8 interception update iff vCPU is in guest mode When updating CR8NVD · CVE-2026-64603 · In the Linux kernel, the following vulnerability has been resolved: platform/x86: intel-hid: Protect ACPI notify handler against recursion Since commit e2ffcda1NVD · CVE-2026-64602 · In the Linux kernel, the following vulnerability has been resolved: iio: adc: spear: Initialize completion before requesting IRQ In the report from Jaeyoung ChuNVD · CVE-2026-64601 · In the Linux kernel, the following vulnerability has been resolved: ALSA: us144mkii: capture_urb_complete: redundant usb_anchor_urb corrupts anchor list on eachCISA KEV · CVE-2026-20349 · Cisco Secure Firewall Adaptive Security Appliance (ASA) and Secure Firewall Threat Defense (FTD) Heap Inspection Vulnerability · Added 2026-08-11 · Due 2026-08-14CISA KEV · CVE-2026-68820 · Microsoft Windows Ancillary Function Driver for WinSock Use-After-Free Vulnerability · Added 2026-08-11 · Due 2026-08-25

Vendors · smiths-medical

smiths-medical

· Vendor

Total CVEs

10

Critical

0

Products

2

Search All CVEs →

10

Recent Vulnerabilities

View all 10
CVE-2017-12726

A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module.

CVE-2017-12725

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection.

CVE-2017-12724

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections.

CVE-2017-12723

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications.

CVE-2017-12722

An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module.

CVE-2017-12721

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle (MITM) attack.

CVE-2017-12720

An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections.

CVE-2017-12718

A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.

CVE-2016-8358

An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-the-middle attacker to gain access to the communication channel between endpoints.

CVE-2016-8355

An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database, which would allow an authenticated user to modify drug libraries, add and delete users, and change user permissions. According to Smiths-Medical, physical access to the pump is required to install drug library updates.