361,800
Total CVEs
26,223
Critical
85,816
High
1,626
CISA KEV
1,172
This Week
172 results · Page 2/7
Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, and MELSEC iQ-F Series FX5-ENET/IP Ethernet Module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.
Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products.
Dead Code vulnerability in Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, and Mitsubishi Electric Iconics Digital Solutions ICONICS Suite Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3 allows a local authenticated attacker to execute a malicious code by tampering with a specially crafted DLL. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products.